Conversion using the Refrigeration Tons to KW Calculation Formula
The formula to convert Refrigeration Tons (RT) to Kilowatts (kW) is:
- RT = Refrigeration Tons
- KW = Kilowatts
- 3.51685 = Conversion factor (1 RT = 3.51685 kW)
Where:
Suggested Reading
- Micro Farad To Kvar Conversion Calculator
- Bus Bar Size Conversion Calculator
- Va To Amps Conversion Calculator
- Motor Speed Conversion Calculator
- Output Voltage Conversion Calculator
- Kwh To Kw Conversion Calculator
- Ampere Hours To Coulombs Conversion Calculator
- SCR Gate Resistor Design Tool
- DIY diode voltage calculator
- Rms Voltage Conversion Calculator
- Bhp To Kilowatts Conversion Calculator
- Refrigeration Tons To Kilowatts Conversion
- Rms Voltage Vrms Conversion Calculator
- Kvar To Farad Conversion Calculator
- transformer magnetizing current loss calculator
- Amperes To Horsepower Conversion Calculator
- cable diameter calculator free
- cable amperage calculator simple
Refrigeration Tons to Kilowatts conversion chart
Refrigeration Tons (RT) | Kilowatts (kW) |
---|---|
0.5 | 1.7584 |
1 | 3.5169 |
2 | 7.0337 |
5 | 17.5843 |
10 | 35.1685 |
20 | 70.337 |
50 | 175.8425 |
100 | 351.685 |
Frequently Asked Questions - Refrigeration Tons to KW Calculate Conversion FAQs:
How do you convert Refrigeration Tons to Kilowatts (KW)?
The conversion method for refrigeration tons into kilowatts depends on the formula KW = tons × 3.517. A cooling capacity measurement of ten refrigeration tons translates to 35.17 kilowatts. The conversion serves as a crucial step for HVAC system design practices as well as energy calculation processes.
What is the relationship between Refrigeration Tons and power consumption in KW?
Actual electrical usage stands lower than one refrigeration ton (3.517 kW) cooling capacity because of system efficiency (COP). The electric power requirement of a 10-ton system reaches 11.72 kW when it operates with a COP value of 3.
How do you calculate energy efficiency using Tons to KW conversion?
The efficiency calculation requires division of cooling capacity (tons × 3.517) by actual power input measured in kW. System performance and operating cost analysis depends on the calculated ratio (COP). Higher values of the COP rate show better efficiency in operation.
Why is Tons to KW conversion important for HVAC system design?
System sizing and power supply planning, along with international specifications, require an accurate conversion between tons and kW. Cold-load matching and precise energy need assessment functions become possible because of this calculation.
How do you determine operating costs using Tons to KW calculations?
A cost calculation method starts with ton-to-kW conversion and incorporation of efficiency data through COP values, followed by multiplication by hours in operation and the price rate of electricity in dollars per kilowatt hour. A 10-ton piece of equipment operating using 11.72 kilowatts for 8 hours at $0.12 per kilowatt hour will amount to $11.25 in daily costs.